Loop-H3300-3S G.SHDSL Stand Alone

Features
  • 1-pair/2-pair/1+1 G.SHDSL (Annex A,B) mode selectable
  • 1 pair G.SHDSL.bis (Annex F) (future option)
    STU-C(master) or STU-R(slave.) mode selectable
  • Support router or bridge mode
  • Built in self-test, loopback and QRSS functions interface
  • hybrid co-existence in one chassis
  • Local/remote management through console port, LAN or WAN
 
  • Log-in and password security protection
  • VT100 Firmware Download
  • Support configuration upload/download
  • SNMP and Telnet are supported
  • Multi-color LED indicators
  • Optional front panel keys and 2-line by 16-character LCD
    display.
  • Standard compliance:
  • G.SHDSL: ITU-T G.991.2 Annex A,B
    ¾ Transmission rate up to 2.304M bps on 1-pair
    ¾ Transmission rate up to 4.608M bps on 2-pair
Description
The Loop-H3300-3S is an addition to our H3300 family of CPE products that are based on the G.SHDSL transmission
standard. They use the standard 16/32-TCPAM line format over twisted copper pairs to provide digital transport for a
variety of data formats and data rates.

The distances that this technology can span without repeaters are dependent on the data rate. Loop-H 3300-3S
provides high speed transport for a T1/E1 link plus an additional Ethernet bridge, V.35 data transport over one (1)
or two (2) twisted copper pairs.

The H3300 works as a pair (as master and slave) or as slave unit to the either one of the two master units:
AM3440’s G.SHDSL card, H3300 rack and H3300 standalone.

The Loop-H3300-3S can be configured as master or slave, or as the slave side of the G.SHDSL link with the other
master being the AM3440’s G.SHDSL card, H3300 rack card or H3300 standalone unit. The master unit is usually
located in central offices and is usually a rack-mounted model. The slave unit is usually located at customer's
premises and is usually a stand-alone model.


Ordering Information

To specify options, choose from list below:
Note: RoHS compliant units are identified by the letter G appearing immediately at the end of ordering code.

AC power cord for Australia

Where Port1 = ERJ : E1 with RJ48C BNC : E1 with BNC TRJ : T1 Note: If Port1 is not required, omit the Port1 field in the ordering code.

Port2 =

11 : V.35 with M34 Connector Note: If Port2 is not required, omit the Port2 field in the ordering code.

Port3 = BG : Bridge, also SNMPRT : Router , also Bridge, SNMP Note: If Port3 is not required, omit the Port3 field in the ordering code.

SP=kk for 1-pair line rate Nx64K bps (G.SHDSL Annex A, B. N=3 to 36)mm for 2-pair line rate Nx64K bps (G.SHDSL Annex A, B. N=3 to 36)kb for 1-pair line rate Nx64K bps (G.SHDSL.bis Annex F. N=3 to 89) (future option)

PP=

non RoHS compliant RoHScompliant Description
P1 Available Available for -48 Vdc
P2 Available Available for 100-240 Vac Please choose an appropriate power cord
P6 Available Available for -48 Vdc with sealing current looped
P7 Available Available for 100-240 Vac with sealing current looped (For AC choose an appropriate power cord)
P9 Available Available for combination AC and DC (100-240 Vac and -48 Vdc dual-feed). Please choose an appropriate power cord.
For Example:

Loop-H3300-3C-ERJ-11-kk-P9

For model H3300-3C G.SHDSL stand-alone device with LCD and LED display, E1 withRJ48C connector, V.35 with M11 connector, 1-pair line rate Nx64K bps (G.SHDSL N=3 to 36) and combination AC and DC power (100-240 Vac and -48 Vdc dual-feed).


Enter and submit form and we will contact you straight away:

 Please specify the Brand and Model Number:

* Brand & Model
* Product type (modem, router, etc.)
Part # (if available):
*Qty.
Specs/Features/Description

 *I am the End User Reseller (tax-ID required at time of purchase)

Describe your application requirements with as much detail as possible:   

  Contact  Information - Our Privacy Policy is: We do not sell, trade, give or share information
   provided to us to anyone.

    First Name: Last Name: Title: 
    Company:   Mail Stop:   

    Address:    
    City:            State: Postal Code:  Country:
    Telephone: FAX:   
    Email:         URL:   

Enter the code below as it is shown:

    

Enter and submit form and we will contact you straight away:

 Please specify the Brand and Model Number:

* Brand & Model
* Product type (modem, router, etc.)
Part # (if available):
*Qty.
Specs/Features/Description

 *I am the End User Reseller (tax-ID required at time of purchase)

Describe your application requirements with as much detail as possible:   

  Contact  Information - Our Privacy Policy is: We do not sell, trade, give or share information
   provided to us to anyone.

    First Name: Last Name: Title: 
    Company:   Mail Stop:   

    Address:    
    City:            State: Postal Code:  Country:
    Telephone: FAX:   
    Email:         URL:   

Enter the code below as it is shown:

    
The Loop-H3300-3S is an addition to our H3300 family of CPE products that are based on the G.SHDSL transmission
standard. They use the standard 16/32-TCPAM line format over twisted copper pairs to provide digital transport for a
variety of data formats and data rates.

The distances that this technology can span without repeaters are dependent on the data rate. Loop-H 3300-3S
provides high speed transport for a T1/E1 link plus an additional Ethernet bridge, V.35 data transport over one (1)
or two (2) twisted copper pairs.

The H3300 works as a pair (as master and slave) or as slave unit to the either one of the two master units:
AM3440’s G.SHDSL card, H3300 rack and H3300 standalone.

The Loop-H3300-3S can be configured as master or slave, or as the slave side of the G.SHDSL link with the other
master being the AM3440’s G.SHDSL card, H3300 rack card or H3300 standalone unit. The master unit is usually
located in central offices and is usually a rack-mounted model. The slave unit is usually located at customer's
premises and is usually a stand-alone model.

Performance Monitor (E1/ T1)
Performance Store The last 24 hours performance in 15-minute intervals and last 7 days in 24-hour summary
Monitor Registers Network, E1/ T1/ DTE, and remote site
Performance Reports Errored Second, Unavailable Second, Severe Errored Second
Alarm Status Alarm Type, Loop1, Loop2, E1/ T1(LOS, ES, SES), and DTE Clock Loss
Alarm History Contains 256 alarm records which record the latest alarm type, and date & time
xDSL Line Interface
SHDSL standard ITU-T G991.2 / G994.1
Full duplex with adaptive echo cancellation 16PAM line coding
One or two unconditioned 19-26 AWG twisted pairs
Line Rate Available (N x 64K+ 8K) bps, N =3 to 36 (2.304M+8K) bps for 1-pair G.SHDSL
(N x 64K+ 8K) bps, N =3 to 72 (4.608M+8K) bps for 2-pair G.SHDSL
(N x 64K+ 8K) bps, N =3 to 89 (5.696M+8K) bps for 1-pair G.SHDSL.bis (future option)
Clock
xDSL looped, Internal, or E1/ T1/ DTE
Console Port
Connector DB9S at front panel
Electrical RS232 interface (DCE)
Protocol Menu driven VT-100 terminal
System Configuration Parameters (All in non-volatile memory)
Active Configuration Current working configuration
Default Configuration Manufacture default configuration
Diagnostics Test
xDSL Loopback To-DTE, To-LINE
DTE Loopback To-DTE, To-LINE
E1 Loopback To-E1, To-LINE
T1 Loopback To-T1, To-LINE
Slave Loopback DTE-Side, Line-Side (through EOC and V.54)
Front Panel
Keypad 4 keys left arrow, right arrow, ESC, and ENTER
LCD 2-line by 16-character
LED Indicators

Physical/Electrical
Dimensions 29 x 6 x 22 cm (W x H x D)
Power 8 Watts max without line power
Temperature Range 0 – 50 °C
Humidity 0 – 95% RH (non-condensing)
Mounting Desk-top stackable
Rack Mount tray available
Compliance
EMI/EMC EN55022 EN50081-1 EN50082-1
Safety EN60950
ITU-T G.991.2 (G.SHDSL Annex A, B)
G.991.2 (G.SHDSL.bis Annex F)
G.994.1


 

TRANSLATE THIS WEBSITE
INTO YOUR PREFERRED LANGUAGE


| Home | Products Search | Order | email |

National Data Mux. - All products, logo's and brand names mentioned are trademarks or registered trademarks of their respective owners.